Acier Lintels
Home Literature Projects Recruitment Contact Us

95-110mm Cavity - Wide Inner Leaf

L1/S WIL 100
 

For 95-110mm cavity wall with wide inner block/brick construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
  L1/S WIL 100

* A continuous bottom plate added
Note:Maximum block dimensions 150mm (95mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1200
1350
1800
1950
2400
2550
3000
*3150
3600
*3750
4200
                           
Height ‘h’
82
107
142
177
188
188
       
Thickness ‘t’
2
2
2
2.6
3.2
3.2
       
Total UDL(kN) Load ratio (1)
13
17
23
24
30
27
       
Total UDL(kN) Load ratio (2)
11
14
18
18
26
25
       


L1/HD WIL 100
 

For 95-110mm cavity wall with wide inner block/brick construction.
Heavy duty loading condition.

List
Price:
www.iglintelsprices.com
  L1/HD WIL 100

* A continuous bottom plate added
Note:Maximum block dimensions 150mm (95mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1200
*1350
1500
*1650
1800
*1950
2100
*2250
2700
                                  
Height ‘h’
113
135
165
165
188
         
Thickness ‘t’
3.2
3.2
3.2
3.2
3.2
         
Total UDL(kN) Load ratio (1)
20
25
35
30
36
         
Total UDL(kN) Load ratio (2)
17
22
27
25
32
         


L1/XHD WIL 100
 

For 95-110mm cavity wall with wide inner block/brick construction.
Extra heavy duty loading condition.

List
Price:
www.iglintelsprices.com
  L1/XHD WIL 100

* A continuous bottom plate added
Note:Maximum block dimensions 150mm (95mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
*0600
1500
*1650
1800
*1950
2100
                                                
Height ‘h’
165
188
188
             
Thickness ‘t’
3.2
3.2
3.2
             
Total UDL(kN) Load ratio (1)
45
45
50
             
Total UDL(kN) Load ratio (2)
40
40
40
             