110-150mm Cavity Wall Lintels

L1/S 110
 

For 110-125mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
  L1/S 110

* A continuous bottom plate added
Note:Maximum block dimensions 125mm (110mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1500
1650
1800
1950
2100
*2250
3000
*3150
4050
*4200
4800
                           
Height ‘h’
95
121
145
195
195
195
       
Thickness ‘t’
2
2
2.6
2.9
3.2
3.2
       
Total UDL(kN) Load ratio (1)
16
22
24
27
26
25
       
Total UDL(kN) Load ratio (2)
13
18
18
22
19
20
       


L1/S 130
 

For 130-145mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
  L1/S 130

* A continuous bottom plate added
Note:Maximum block dimensions 125mm (130mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications



Manufactured Length
150mm increments
0600
1500
1650
1800
1950
2100
*2550
3000
*3150
4050
*4200
4800
                           
Height ‘h’
103
128
190
190
190
190
       
Thickness ‘t’
2
2
2.6
2.9
3.2
3.2
       
Total UDL(kN) Load ratio (1)
16
22
24
27
26
25
       
Total UDL(kN) Load ratio (2)
13
18
18
22
19
20
       


L1/S 150
 

For 150-165mm cavity wall construction.
Standard duty loading condition.

List
Price:
www.iglintelsprices.com
  L1/S 150

* A continuous bottom plate added
Note:Maximum block dimensions 125mm (150mm cavity)
Load ratio 1 - applies to loads with an inner to outer leaf ratio of between 1 :1 and 3 :1.
This ratio is normally applicable to lintels that support: a. masonry b. masonry and timber floors
Load ratio 2 - applies to loads with an inner to outer leaf ratio of between 4 :1 and 19:1.
This ratio is normally applicable to lintels supporting: a. constructions with concrete floors b. eaves applications

Manufactured Length
150mm increments
0600
1500
1650
1800
1950
2100
*2250
3000
*3150
*4050
4200
4800
                           
Height ‘h’
100
125
180
180
180
180
       
Thickness ‘t’
2
2
2.6
2.9
3.2
3.2
       
Total UDL(kN) Load ratio (1)
16
22
24
27
26
25
       
Total UDL(kN) Load ratio (2)
13
18
18
22
19
20
       